Specifications
FPT-40 Installation & Operation Guide  Page 3-7 
Figure 3-5 Software Setup for Connection Type 
Step 9.  In the Connection field, select the type of connection you are 
using to communicate with the FPT-40 terminal(s). The 
required information in the Connection Info depends on your 
connection. 
  Ethernet: The FPT-40 terminals communicate to the Host 
PC via Ethernet connection. If selected, you must enter the 
IP Address and Port 4370
. [Obtain the correct IP address 
from your network administrator, or alternatively, please 
consult Chapter 3: Network Configuration of this Guide for 
additional information about hardware configuration]. 
Note:  The Port number for Ethernet terminals must
 be set to; 
MTX-15 = 2101, MTX-10 & 20 = 401, FPT-40 = 4370, and 
HandPunch’s = 3001. 
  Direct: The FPT-40 terminal(s) are directly connected to 
the Host PC via Com Port. If selected, you must select the 
Com Port and Baud Rate. 
Step 10. Click on the Terminals tab to add, edit, delete, or 
communicate with FPT-40 terminals. 