Specifications

FPT-40 Installation & Operation Guide Page 3-7
Figure 3-5 Software Setup for Connection Type
Step 9. In the Connection field, select the type of connection you are
using to communicate with the FPT-40 terminal(s). The
required information in the Connection Info depends on your
connection.
Ethernet: The FPT-40 terminals communicate to the Host
PC via Ethernet connection. If selected, you must enter the
IP Address and Port 4370
. [Obtain the correct IP address
from your network administrator, or alternatively, please
consult Chapter 3: Network Configuration of this Guide for
additional information about hardware configuration].
Note: The Port number for Ethernet terminals must
be set to;
MTX-15 = 2101, MTX-10 & 20 = 401, FPT-40 = 4370, and
HandPunch’s = 3001.
Direct: The FPT-40 terminal(s) are directly connected to
the Host PC via Com Port. If selected, you must select the
Com Port and Baud Rate.
Step 10. Click on the Terminals tab to add, edit, delete, or
communicate with FPT-40 terminals.