Specifications
FPT-40 Installation & Operation Guide Page 1-7
The connections between the host PC and multiple serial terminals for
this application are as follows:
Time Guardian
Host PC
+
+
+
+
+
+
5
2
1
3
6
4
3: SHIELD
5: + WHITE
6: (-) BLUE
CommStik
Communications
Cable
Amano
P/N - AUS-100353
A
mano
P/N AMX-206950
A
mano
P/N AMX-206700
Figure 1-4 Multiple Direct Connect Serial Terminals
* The maximum number of terminals is dependent upon the distance and
the quality of cabling used. It is recommended that Belden Low Voltage
Computer Cable, P/N 9841 or equivalent, be used to connect the
junction boxes for this application.
Warning! Please note that terminal #3 (used for the RS-485 cable
Shield) is disconnected from the internal RJ-11
receptacle of the junction box. This is deliberate; the
shield connection is NOT fed through to the Terminal.
Time & Attendance
Software
PC Host