User guide
Time Guardian Series – Nexus Lite Module  23-19 
4.  In the TZ (Time Zone) Offset fields, select the time zone difference (if applicable) between 
the physical location of your PC and the terminals in Hours and Minutes.
5.  The Output Path field is not used and grayed out. 
6.  The “Secondary Output File” box is not used and grayed out. 
7.  The DLS (Daylight Savings Time) Settings are not used and grayed out. 
8.  Click on the Connection tab. 
9.  In the Connection field, Ethernet is fixed for the type of connection you are using to 
communicate with the terminal(s). The terminals communicate to the Host PC via Ethernet 
connection. You must enter the IP Address and Port (default port = 10,005). [Obtain the 
correct IP address from your network administrator, or alternatively, please consult the 
appropriate terminal manual to perform terminal diagnostics, hardware configuration, and 
identify the IP address]. 
10. Click on the Select Terminals 
 button to see a list of discovered terminals (see 
figure). The Ethernet connected terminals in this location should appear in the Terminals list 
(see figure). The User Datagram Protocol (UDP) Output of the Nexus Lite must 
be set to the 
IP Address of the NLM client PC. Also, NLM utilizes a UDP Service which runs in the 
background on the NLM client. The UDP Service must be running for this communication. 
The “Receiving Port Number” on the Nexus Lite must
 be set to the same as the NLM client 
which has a default = 4445. (See Network Module). 