14 Amano TCX-22 Operation Manual
Setting End Daylight Saving Time
Note: The government standard for DST is subject to change. Your clock is
factory-set for correct DST based upon when it was manufactured, but any
revision to DST begin or end dates may require updating the system-set
DST calendar.
The steps below change the end date for DST. DST is enabled and
disabled in the Main Programming Menu. Updating the end date for DST
needs to be done just one time*, since the clock's rolling calendar function
will auto-calculate the end date for each year thereafter.
1. When the display flashes 17 EdL , press the ENTER
button.
2. Press the CHANGE button until the correct year
appears, then press the ENTER button.
3. Press the CHANGE button until the correct month
appears, then press the ENTER button.
4. Press the CHANGE button until the correct date
appears, then press the ENTER button.
5. When the display flashes the correct year, month and
date, press the ENTER button.
6. When the display flashes 17 EdL
, press the CHANGE
button to move to the Diagnostics Mode (see Exit
Program Mode to end).
The Diagnostic Routine
The Diagnostic Routine checks the LCD segments, the number of prints,
and clears the memory (Print Style, Language, Leading Zero Suppress,
Clock and Calendar, Right/Left Print and Daylight Saving Time features).
1. When the display flashes I8 dlA9, press the
ENTER button. The Diagnostic Routine consists of
the following:
Menu Code Menu Function
d1 LCd
Tests the segments of the LCD
d2 NPr
Displays total number of print outs
d3 Clr
Clears memory and restores default settings