Operation Manual
CP-5000 User’s Guide 4-17
Note: The duration (1 to 15 seconds) that the Buzzer will be ON for is
set in the Signal Duration menu (page 4-14).
7. Press the Change key to enter a value of “0” to
disable (OFF) or “1” to enable (ON) Signal.
When the correct value appears in the display,
press the Enter key. The display will move to
the next object, Color.
Note: The duration (1 to 15 seconds) that the relay contacts of Signal
will be closed is set in the Signal Duration menu (page 4-14).
8. Press the Change key to enter a value of “1” to
change to black ink, or “2” to change to red ink.
Note: If you program a color change, you must
program another step or schedule to return the ribbon to its
original color.
9. When the desired value is displayed, press Enter
key. The program number, days of the week, and
time of the day that the program will be activated
will flash in the display. To edit these settings,
press the Change key. This will return you to the
display described in step 1. To save these
settings, press the Enter key. When saved, the
display will move to the next program number.
10. Repeat the previous steps to enter in the next
program. If a mistake is made at any time, the
fastest way to return to the Weekly program to
be changed is to select the Function key and
cycle through the other programming options
until the Weekly programming reappears.
Warning!: Do not schedule to programs to occur at the same time;
the results will be inconsistent and unpredictable.