Operation Manual

CP-5000 User’s Guide 2-7
3. Strip approximately .25” (6 mm) of insulation off the ends of the wires
that will be connected to the CP-5000.
4. Remove the top cover from the CP-5000.
5. Remove the front cover; support the cover so that it doesn’t hang
from the ground wire.
6. With the unit flat and face up, locate terminal block TB1.
7. Using a small-blade screwdriver, loosen the screws on the TB1 side
of the connector block.
8. Observing polarity, insert one wire into the CP-5000 through the
open hole and connect it to the proper terminal position of TB1.
Using a screwdriver, secure the wire in place. Insert the other wire
into the unit and secure in place. Make sure that only the stripped
wire is clamped, and not the insulation.
9. Check the connections by tugging on each wire. If they appear loose,
repeat the previous step.
10. Clamp the signal wires as shown in the following drawing using a
cable clamp appropriate to your cable thickness.