8.  Prepare Range Hood Vents 
andMounting Tabs
 ■ Install Strain Relief
Install a UL listed/CSA approved 1/2" (13 mm) 
strainrelief(A).
 ■ Mounting Tabs
Start a #8-18 x 5/8" (4.2 x 16 mm) truss-head screw into 
themounting tab (D) on each side of the range hood 
asshown in the inset. Insert the screws approximately 
2turns into the mounting tab holes.
 ■ Non-vented (Recirculating) Installations
Using a #2 Phillips screwdriver remove the 2 screws 
andremove the top, front rectangular vent cover (D). 
GotoStep12.
 ■ 3
1
/
4
" x 10" (8.3 x 25.4 cm) Rectangular Vent Installations
For top vent installations, remove the top rectangular 
ventknockout (C).
OR
For wall vent installations, remove the rear rectangular 
ventknockout (B).
9.  Attach Vent Damper or Transition
3
1
/
4
" x 10" (8.3 x 25.4 cm) Rectangular Vent Damper
Using (2) short Phillips head screws, install the 3
1
/
4
" x 10" 
(8.3 x25.4 cm) rectangular damper over the top or rear 
ventknockout removed in Step 8.
NOTE: If the wall cap used has a damper and it interferes with 
the rectangular damper, remove the rectangular damper ap.
10. Mount Range Hood
 ■ Lift the range hood into place, positioning the rear slots 
overthe mounting brackets.
 ■ Using a Phillips screwdriver, push on the screws that 
arestarted into the top mounting tabs and bend the 
tabsagainst the cabinet side walls. Attach the screws 
tothecabinet side walls.
IMPORTANT: Do not overtighten the screws.
 ■ For direct wire installations, run the home power supply 
cable according to the National Electric Code or CSA 
standards and local codes and ordinances. There must 
beenough wiring from the fused disconnect (or circuit 
breaker) box to make the connection in the range hood 
electrical terminal box.
 ■ Tighten the strain relief screws.
NOTE: Do not reconnect power until the installation 
iscomplete.
OPTIONAL: If you prefer, bend the rear tabs against 
therearof the range hood and attach to the wall using 
#8-18x 5/8" (4.2 x 1.6 cm) truss-head screws.
11. Connect Vent System
 ■ Connect the ventwork to the range hood.
 ■ Seal joints with vent clamps or duct tape to make 
secureandairtight.
 ■ Check that the backdraft dampers work properly.
A