Product specifications
Product SPecificationS
4 www.amana-hac.com SS-AMH95
SS-AMH95 www.amana-hac.com 5
MiniMuM cleArAnces to coMbustible MAteriAls
Upow 0” 0” 1” C 0” 1”
Horizontal 6” 0” 1” C 0” 4”
C=Ifplacedoncombusbleoor,theoorMUSTbewoodONLY.
• For servicing or cleaning, a 24” front clearance is recommended.
•
Unitconnecons(electrical,ue,anddrain)maynecessitategreaterclearancesthantheminimumclearanceslistedabove.
• Inallcases,accessibilityclearancemusttakeprecedenceoverclearancesfromtheenclosurewhereaccessibility
clearances are greater.
•
Approvedforlinecontactinthehorizontalposion.
DiMensions
A B C D E
AMH950453BXA
17½” 16” 13⅛” 12⅛” 13⅝”
AMH950703BXA
17½” 16” 13⅛” 12⅛” 13⅝”
AMH950704CXA
21” 19½” 16⅛” 16” 17½”
AMH950904CXA
21” 19½” 16⅛” 16” 17½”
AMH950905CXA
21” 19½” 16⅛” 16” 17½”
AMH951155DXA
24½” 23” 20⅝” 19⅜” 20⅞”
• InstallermustsupplyoneortwoPVCpipes:oneforcombusonair(oponal)andonefortheueoutlet(required).Ventpipe
mustbeeither2”or3”indiameter,dependinguponfurnaceinput,numberofelbows,lengthofrun,andinstallaon(1or2pipes).
Theoponalcombusonairpipeisdependentoninstallaon/coderequirementsandmustbe2”or3”diameterPVC.
• Linevoltagewiringcanenterthroughtherightorlesideoffurnace.Low-voltagewiringcanenterthroughtherightorlesideoffurnace.
• Conversionkitsforhigh-altudenaturalgasoperaonareavailable.ContactyourAmanadistributorordealerfordetails.
• Installermustsupplythefollowinggaslinengs,accordingtowhichentranceisused:
Le:One90ºstreetelbow;one2½”pipenipple;one90ºelbow;straightpipe;onegroundjointunion
Right: Straight pipe to reach gas valve
• Installaonsusingaboomreturn:Failuretounfoldangeswillreduceairowareabyapproximately18%.Thiscouldresult
in performance and noise issues.
COMPONENT IDENTIFICATION
6
GMH95*****XA*
Cabinet Size A B C D E
13-5/8
17-1/2
20-7/8
All dimensions are in inches.
24-1/2
12-1/8
16
19-3/8
12-15/16
15-15/16
20-7/16
GMH950453BXA*
GMH950703BXA*
GMH950704CXA*
GMH950904CXA*
GMH950905DXA*
GMH951155DXA*
16
19-1/2
23
17-1/2
21
RIGHT SIDE
DRAIN LINE
HOLES
AIR
INTAKE
PIPE
2" PVC
1 5/8
RIGHT SIDE VIEW
2
1 1/2
UNFOLDED FLANGES
1
FOLDED FLANGES
UNFOLDED FLANGES
FOLDED FLANGES
AIR
DISCHARGE
AIR
DISCHARGE
NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and
noise issues.
19 7/8”