Service manual
SERVICING
50
Power to System
Thermostat calls for heat
Control board applies power to 
Air circulating blower (ACB) 
cooling speed. Pilot and Igniter 
are locked out.
"Smart Valve" checks Igniter 
circuit and valve
System shuts down..
"Smart Valve" powers Igniter, 
opens pilot valve. 
Pilot Lights, Flame Rod 
Senses Flame
Igniter Off 
Main Valve Opens 
Main burner Lights 
Smart Valve sends signal 
(24V) to control board.
Thermostat Ends "Call 
for Heat" 
Main and Pilot Valves Close 
Control board times out. 
De-energizes power to 
blower (ACB)
Igniter stays on 
Pilot valve remains 
open
Main valve closes
Pilot and main valves 
close. 
System shuts down.
Start
Self Check
Ignition
Main 
Burner 
Operation
End
Limit(s) open
Igniter 
Missing 
or Broken
Limits closed
No
Flame outage 
occurs during 
run cycle
Igniter 
opens
Board checks limit circuit 
Igniter and gas 
valve check OK
Yes
Control board times out, 
applies power to blower 
(ACB) heating speed.
Honeywell Smart Valve Sequence of Operation 
SV9500