Ventless Submittal Information

225 49
th
Ave. Dr. SW, Cedar Rapids, IA 52404
800-233-2366, 319-368-8120, Fax: 319-368-8198
www.acpsolutions.com
ARX2 / MRX2 Estimated Heat Load Calculations
ARX2/MRX2 (single phase)
Parameters
Operating Time 12 Hours
Energy Costs $0.11 KWHr
Idle Time 2 Hours
Cook Cycles/Daily 100
Typical Cook Time 60 Seconds
Data
Time
(Minutes)
Power
(Watts)
kWh Cost/Day
Balance of
Time
(Hours)
Warm Up
8.6
3,150
0.5
$0.05
11.86
Cooking
100
4,953
8.3
$0.91
10.19
Idle Time
611.4
768
7.8
$0.86
0.00
TOTAL COST PER DAY
$1.82
TOTAL COST PER MONTH
$54.55
TOTAL COST PER YEAR
$654.65
HVAC Requirements per Operating Time (Estimated)
Average
Energy
Cooking
and Idle
Warm-Up
Energy
Total
Energy
Total
Average
Power
Total
Environmental
Load
Average
Cooling
Requirement
57,892 kJ 1,622 kJ 59,514 kJ 1,378 W 4,700 Btu/hr
0.39 Tons of
AC
Page 11 of 26