Integrated control module will automatically attempt to reset from lockout after one hour.
Troubleshooting Chart
Furnace lockout due
to an excessive
number of ignition
“retries” (3 total) or
“recycles (5 total)
1
.
Locate and correct gas
interruption.
Replace or realign
igniter.
Check flame sense
signal. Sand sensor if
coated and/or oxidized.
Check flue piping for
blockage, proper
length, elbows, and
termination.
Verify proper induced
draft blower perfor-
mance.
Turn power OFF
prior to repair.
Igniter is fragile,
handle with care.
Sand flame sensor
with emery cloth.
See “Combustion
and Ventilation Air
Requirements” and
“Category I Venting
(Vertical Venting)”
section for details.
Furnace fails to operate.
Integrated control module
diagnostic LED is
flashing ONE (1) flash.
1
1 FLASH
Failure to establish flame.
Cause may be no gas to
burners, bad igniter or igniter
alignment, improper orifices,
or coated/oxidized or
improperly connected flame
sensor.
Loss of flame after establish-
ment. Cause may be
interrupted gas supply, lazy
burner flames (improper gas
pressure or restriction in flue
or improper induced draft
blower performance.
Pressure switch
circuit is closed.
Induced draft blower
is not operating.
Replace induced draft
blower pressure switch.
Repair short.
Turn power OFF
prior to repair.
Replace pressure
switch with proper
replacement part.
Furnace fails to operate.
Integrated control module
diagnostic LED is
flashing TWO (2) flashes.
2
2 FLASHES
Induced draft blower
pressure switch contacts
sticking.
Shorts in pressure switch
circuit.
Inspect pressure
switch hose. Repair, if
necessary,
Inspect flue for
blockage, proper
length, elbows, and
termination.
Correct pressure switch
setpoint or contact
motion.
Tighten or correct
wiring connection.
Pressure switch hose
blocked, pinched or
connected improperly.
Blocked flue or weak
induced draft blower.
Incorrect pressure switch
setpoint or malfunctioning
switch contacts.
Loose or improperly
connected wiring.
Pressure switch
circuit not closed.
Induced draft blower
is operating.
Induced draft blower runs
continuously with no
further furnace operation.
Integrated control module
diagnostic LED is
flashing THREE (3)
flashes.
3
3 FLASHES
Turn power OFF
prior to repair.
See “Combustion
and Ventilation Air
Requirements”
and “Category I
Venting (Vertical
Venting)” section
for details.
Replace pressure
switch with proper
replacement part.
Integrated control
module has an
internal fault.
Integrated control module
has an internal fault.
Replace bad integrated
control module.
Turn power OFF
prior to repair.
Read precautions
in “Electrostatic
Discharge” section
of manual.
Furnace fails to operate.
Integrated control module
diagnostic LED is lit
continuously.
ON
CONTINUOUS
ON
No 115 volt power to
furnace, or no 24 volt
power to integrated
control module.
Blown fuse or circuit
breaker.
No signal from
thermostat.
Manual disconnect switch
OFF, door switch open, or 24
volt wires improperly
connected or loose.
Blown fuse or circuit
breaker.
Improper thermostat
connection or setting.
Assure 115 and 24 volt
power to furnace
integrated control module.
Check integrated control
module fuse (3A).
Replace if necessary.
Check for possible shorts
in 115 and 24 volt circuits.
Repair as necessary.
Turn power OFF
prior to repair.
Replace integrated
control module fuse
with 3A automotive
fuse.
Furnace fails to operate.
Integrated control module
diagnostic LED provides
no signal.
NONE
Fault Description(s) Possible Causes Corrective Action Cautions and Notes
Symptoms of Abnormal
Operation
Associated
LED Code
2