Technical information
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RT2310003 Rev. 10 December 20002
Illustration Component Test Procedure Results
31823701 Oven light socket Remove one wire from receptacle and
test resistance of terminals.
Measure voltage at oven light.
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring or light switches.
0301491 Rocker switch Measure continuity of switch positions:
Closed
Open
Continuity, if not replace.
Infinite, if not replace.
0305797
NC
NO
C
Door plunger switch Remove switch from unit and measure
the following points:
C-NC
C NO
Plunger in infinite, Plunger out continuity.
Plunger in continuity, Plunger out infinite.
0316767
COM
NC
NO
Door lock switch Test for voltage at terminals to chassis
when in bake, broil, or clean mode.
COM to chassis
Only when latch is engaged:
NC to chassis
120 VAC
120 VAC
31797301
31933401
Autolatch assembly
with door plunger
switch
Disconnect wires and test for
continuity per diagram.
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
M
120 VAC
Motor
Lock/Unlock
Switch
Door
Switch
L1 L2
COM
NC
NO
COM
NC
NO
31933003
31933004
Limits Oven limit
Closed
Open
Fan limit
Closed
Open
See wiring diagram.
210
°
F
240
°
F
155
°
F
115
°
F
31715201
−
LH
31715202
−
RH
Opening
Hinge Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.
CAUTION
!
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.
309145
−
Broil
31939901-Broil
316223
−
Bake
31940001-Bake
Norton ignitor Test for voltage at terminals.
Test for the amount of amperage in the
circuit.
(Ignitor may glow but not have
sufficient amperage to open valve).
120 VAC
3.2
−
3.6 Amps If not replace.
0300664 Dual thermal valve Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Continuity, If not replace.
Continuity, If not replace.
WARNING
!
Do not attempt to open valve with
120 VAC.