Duct Installation Manual
6
BRACKET
TRANSITION
DUCT
MAIN DUCT
MINIMUM
5"
BOTH SIDES
42-27/32" 6" TO 42-1/2"
BRACKET
5"
PARTITION
WALL
DUCT EXTENSION
AIR FLOW
DUCT
TERMINATION
KIT
AIR FLOW
1" to
adjoining
wall
surface
Main Duct and Duct Extension Dimensions
6. In the room where the main duct kit is attached to the
chassis, cut a hole in the wall at the same height from
the floor that the main duct is located. Cut the hole 1/
8” larger than the width and height (10” x 5”) dimen-
sions of the extension duct.
7. Measure from the end of the main duct where the ex-
tension duct will be connected to the hole in the wall.
If necessary cut the extension duct to a length where
the cut end protrudes into the wall’s inner space and
one inch from the adjoining room’s wall surface.
8. Insert the extension duct into the opening in the wall.
Install the extension duct by placing the slotted flange
over the two screws in the main duct. Using two #8
round Phillips head screws, mount bottom of exten-
sion duct to mounting bracket through the bracket slot
(see Main Supply Duct Top Flange illustration).
NOTE: The EDK02 can be cut into two sections and
used with two MDK02s if the needed length does not
exceed 21-1/4”.
Air Baffle Installation Instructions