Specifications
Specifi cation Sheet
www.amana-ptac.com
5
* Approximately 95 CFM with optional power vent kit. Actual vent CFM performance will vary due to application and installation conditions.
**EER - Energy Effi ciency Rating per Air Conditioning & Refrigeration Institute (ARI) Test Procedures and Canadian Standards Association
(CSA) EEV Test Pro ce dures
PTH Models—Reverse Cycle Heating Performance
PTH Model Specifi cations—Cooling/Heat Pump/Electric Heat
See page 4 for Notes and Auxiliary Electric Heater Performance
COP - Coeffi ciency of Performance per ARI Test Procedures Units are rated for capacities and effi ciencies.
Model
1, 7, 9, 10
PTH073B**AJ PTH074B**AE PTH093B**AJ PTH094B**AE PTH123B**AJ PTH124B**AE PTH153B**AJ PTH154B**AE
Voltage
1, 3, 11
230/208 265 230/208 265 230/208 265 230/208 265
Capacity (BTUH) 7,000/6,800 7,000 9,100/8,900 9,100
12,000/11,800
12,000
14,000/13,900
14,000
Amps 2.8/3.0 2.3 3.5/3.8 3.0 4.6/5.0 4.3 6.3/6.9 5.9
Watts 605/585 605 790/775 790 1,110/1,090 1,110 1,505/1,495 1,505
EER 11.6 11.6 11.5 11.5 10.8 10.8 9.3 9.3
Units without Electric Heater
Min. Circuit Ampacity
2, 4
4.0 3.6 5.1 4.4 6.4 5.7 8.8 7.7
CFM
(Cool/Wet Coil)
High
Low
245/240
220/205
245
220
245/240
220/205
245
220
325/315
250/229
325
250
325/315
250/220
325
250
CFM
(Dry Coil)
High
Low
265/260
230/215
265
230
265/260
230/215
265
230
345/335
265/235
345
265
345/335
265/235
345
265
Ventilated Air, CFM
(Fan Only)*
65* 65* 65* 65* 70* 70* 70* 70*
Ventilated Air, CFM
(Compressor and Fan)*
65* 65* 65* 65* 70* 70* 70* 70*
Dehumidifi cation
(Pints/Hr.)
1.6 1.6 2.6 2.6 3.5 3.5 4.4 4.4
Net Weight (lbs.) 95 95 100 100 110 110 115 115
Shipping Weight (lbs.) 110 110 115 115 125 125 130 130
Heating Capacity
1
PTH073B**AJ PTH074B**AE PTH093B**AJ PTH094B**AE PTH123B**AJ PTH124B**AE PTH153B**AJ PTH154B**AE
BTUH
5
6,200/6,000
6,200
8,200/8,000
8,200
10,800/10,600
10,800
13,300/13,200
13,300
Amps 2.6/3.0 2.2 3.2/3.6 2.6 4.5/5.1 3.9 5.7/6.3 5.4
Watts 550/530 550 750/730 750 1,020/1,0 0 0 1,020 1,340/1,330 1,340
COP
5
3.3 3.3 3.2 3.2 3.1 3.1 2.9 2.9
CFM (Dry) 235/230 235 235/230 230 310/290 310 345/335 345
Heating
(BTUH)
5
Outdoor
Ambient
Rating Point
62 °F 7,200/7,000 7,200 9,800/9,600 9,800
13,000/12,800
13,000
15,80 0/15,700
15,80 0
57 °F
6,900/6,700
6,900 9,300/9,100 9,300
12,3 0 0/12,100
12,3 0 0
15,000/14,900
15,000
52 °F
6,500/6,300
6,500
8,700/8,500
8,700
11,6 0 0/11, 4 0 0
11,6 0 0
14,200/14,10 0
14,200
47 °F
6,200/6,000
6,200
8,200/8,000
8,200
10,800/10,600
10,800
13,300/13,200
13,300
COP*
3.3/3.3
3.3 3.2/3.2 3.2 3.1/3.1 3.1 2.9/2.9 2.9
42 °F
5,900/5,700
5,900 7,700/7,500 7,700
10,100/9,900
10,100
12,50 0/12,400
12,50 0
37 °F
5,600/5,400
5,500 7,200/7,000 7,200 9,400/9,200 9,400
11,70 0 /11, 6 0 0
11,70 0
32 °F
5,300/5,100
5,200
6,700/6,500
6,700
8,600/8,400
8,600
10,800/10,700
10,800
27 °F
5,000/4,800
5,000
6,200/6,000
6,200 7,900/7,700 7,900
10,000/9,900
10,000
24 °F
4,800/4,600
4,800
5,900/5,700
5,900 7,500/7,300 7,500 9,500/9,400 9,500
Watts
Outdoor
Ambient
62 °F 580/560 580 810/790 810 1,120/1,100 1,120 1,465/1,455 1,465
57 °F 575/555 575 800/780 800 1,090/1,075 1,090 1,440/1,430 1,440
52 °F 555/535 555 775/755 775 1,060/1,045 1,060 1,405/1,395 1,405
47 °F 550/530 550 750/730 750 1,020/1,0 05 1,020 1,340/1,330 1,340
42 °F 540/525 560 730/710 730 985/970 985 1,325/1,315 1,325
37 °F 530/515 545 705/685 705 950/935 950 1,285/1,275 1,285
32 °F 515/500 535 690/670 690 900/885 900 1,240/1,230 1,240
27 °F 505/490 525 660/640 660 855/840 855 1,190/1,180 1,190
24 °F 500/485 520 640/620 640 830/815 830 1,180/1,170 1,180