Product specifications
SS-PTAC50 www.amana-ptac.com 5
SPECIFICATION SHEET
PTC SPECIFICATIONS — COOLING/ELECTRIC HEAT
Model Description
Cooling Cycle Data
BTU/h Watts EER Amps
PTC105B30AM Cooling w/ electric heat 10,000 / 9,900 910 / 900 11.0 / 11.0 3.6 / 3.8
PTC125B30AM Cooling w/ electric heat 12,000 / 11,800 1,250 / 1,230 9.6 / 9.6 5.0 / 5.2
PTH105B30AM Heat Pump w/ aux. Elec. Heat 9,900 / 9,700 900 / 880 11.0 / 11.0 3.6 / 3.8
PTH125B30AM Heat Pump w/ aux. Elec. Heat 11,800 / 11,600 1,250 / 1,230 9.6 / 9.6 5.0 / 5.2
COOLING DATA
REVERSE CYCLE HEAT PUMP HEATING DATA
Model Description
Reverse Cycle
BTU/h Watts C. O. P.
PTH105B30AM Heat Pump w/ aux. Elec. Heat 9,900 / 9,700 850 / 830 3.4 / 3.4
PTH125B30AM Heat Pump w/ aux. Elec. Heat 11,700 / 11,500 1,180 / 1,160 2.9 / 2.9
ELECTRIC HEAT DATA
Model Description
Electric Heat
BTU/h Watts Amps
PTC105B30AM Cooling w/ electric heat 10,200 / 8,500 3,100 / 2,600 13.1 / 12.0
PTC125B30AM Cooling w/ electric heat 10,200 / 8,500 3,100 / 2,600 13.1 / 12.0
PTH105B30AM Heat Pump w/ aux. Elec. Heat 10,200 / 8,500 3,100 / 2,600 13.1 / 12.0
PTH125B30AM Heat Pump w/ aux. Elec. Heat 10,200 / 8,500 3,100 / 2,600 13.1 / 12.0
Notes:
Important: Maximum overcurrent circuit protection MUST be based on the electric heat data for all units.
PTC and PTH 10 units are based from Domestic 265-volt, 12,000 BTU/h units.
PTC and PTH 12 units are based from Domestic 265-volt, 15,000 BTU/h units.
All units can be available with seacoast protection.
Important: Never operate any unit in ambient conditions above 115° F.
•
•
•
•
•