Specifications
10
SPECIFICATIONS
NOTES:
1. All 265V models must use Amana
®
brand’s subbase (PTSB4**E) or an Amana
®
brand hard wire kit (PTPWHWK4).
2. Minimum branch circuit ampacity ratings conform to the National Electric Code. However, local codes should apply.
3. Minimum voltage on 230/208 volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5 volts.
4. Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265 volt models must be cartridge-style time delay fuses (included
and factory installed on Amana
®
brand all 265 volt chassis).
5. Heating capacity and efficiency are based on unit operation without condensate pump. Unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6. Total watts for 12,000 and 15,000 Btuh models. Subtract 70 watts for PT07/09*B*AE.
7. Please specify 2-digit heater kW size to complete model number.
9. Refrigerant used in all systems is R-22.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09*B*AE.
10. All units meet or exceed ASHRAE 90.1 standards.
11. Some un its less than 250 volts have a Leak Curre nt Detector Interrupter (LCDI) power cord and m eeat UL 484 standards.
12. Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
230V 208V 265V
230/208
2.5/2.0 18,5006,800---2,650/2,14011.6/10.514.5 15 6 - 15 P
230/208
3.5/2.9 112,0009,900---3,650/3,04015.9/14.5 19.9 20 6 - 20 P
230/208
5.0/4.1 1* 17,100 14,000 --- 5,150/4,240 22.4/20.4 28.1 30 6 -30 P
265
2.5 1------8,5002,65010.1 12.7 15 7 - 20 P
265
3.7 1------12,6003,85014.7 18.3 20 7 - 20 P
265
5.0 1* --- --- 17,100 5,150 19.6 24.5 25 7 - 30 P
* PTH/PTC09*B50*G/K have the same airflow as a PTC/P TH12*B***G (not available on 7,000 BTU/h mo dels).
HEAT PERFORMANCE (ELECTRIC HEAT) ELECTRIC DATA
(ALL BTUH SIZES, ALL MODELS)
Nominal Heating
(BTUH)
Number
of
Stages
Electric Heater Size
(kW)
Voltage
Total
Watts
Total
Amps
Minimum
Ampacity
1
Overcurrent
Protection
5
Power
Co r d
1
PTH073B***
E - Y
PTH074B***
E - Y
PTH093B***
E - Y
PTH094B***
E - Y
PTH123B***
E - Y
PTH124B***
E - Y
PTH153B***
E - Y
PTH154B***
E - Y
6,200/6,00 6200 8,200/8,000 8200 10,800/10,600 10800 13,300/13,200 13,300
2.6/3.0 2.2 3.2/3.6 2.6 4.5/5.1 3.9 5.7/6.3 5.4
550/530 550 750/73 0 750 102 0/1,000 1020 1,340/1,330 1,340
3.3 3.3 3.2 3.2 3.1 3.1 2.9 2.9
235/230 235 235/23 0 230 310/2 90 310 345/335 345
Outdoor
Ambient
ºF
Heating BTUH
No te 5
Heati ng B TU H
Note 5
Heating B TUH
Note 5
Heati ng B TU H
Note 5
Heating BT UH
Note 5
Heating BTUH
Note 5
Heatin g BT UH
Note 5
Heatin g BT UH
Note 5
62 7,200/7,000 7,200 9,800/9,600 9,800 13,000/12,800 13,000 15,800/15,700 15,800
57 6,900/6,700 6,900 9,300/9,100 9,300 12,300/12,100 12,300 15,000/14,900 15,000
52 6,500/6,300 6,500 8,700/8,500 8,700 11,600/11,400 11,600 14,200/14,100 14,200
47 6,200/6,000 6,200 8200/8,000 8,200 10,800/10,600 10,800 13,300/13,200 13,300
Ra tin g
Point
(COP) 3.3/3.3 3.3 3.2/3.2 3.2 3.1/3.1 3.1 2.9/2.9 2.9
452 5,900/5,700 5,900 7,700/7,500 7,700 10,100/9,900 10,100 12,500/12,400 12,500
37 5,600/5,400 5,500 7,200/7,00 7,200 9,400/9 ,200 9,4 00 11,700/11,600 11,700
32 5,300/5,100 5,200 6,700/6,500 6,700 7,900/7,700 7,9 00 10,000/9,900 1 0,000
Outdoor
Ambient
ºF
Watts Wat ts Wa tts Watts Watts Watts Watts Watts
62 580/560 580 810/790 810 1,120/1,100 1,1 20 1,465/1,455 1,465
57 575/555 575 800/780 800 1,090/1,075 1,0 90 1,440/1,430 1,440
52 555/535 555 775/755 775 1,060/1,045 1,0 60 1,405/1,395 1,405
47 550/530 550 750/730 750 1,020/1,005 1,0 20 1,340/1,330 1,340
42 540/525 560 730/710 730 985/970 985 1,325/1,315 1,325
37 530/515 545 705/685 705 950/935 950 1,285/1,275 1,285
32 515/500 535 690/670 690 900/885 900 1,240/1,230 1,190
HEAT ING PERFORMANCE - REVERSE CYCLE
BTUH
5
COP
5
CFM (Dr y)
Heating Capacity
Rever se Cycl e
1& 7
Amps
12
Watts