Specification
PRODUCT MODEL NUMBERS
Because Whirlpool Corporation includes a continuous commitment to improve our 
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation 
Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
Ref. W10545337B
07/14/2016
30" (76.2 cm) Freestanding Gas Range
AGR6603SFAGR6303MF
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is 
required. A time-delay fuse or circuit breaker is also recommended. 
It is recommended that a separate circuit serving only this range be 
provided.
GAS SUPPLY REQUIREMENTS
Type of gas
Natural gas:
 ■ This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located on the 
oven frame behind the top left side of the oven door has information 
on the types of gas that can be used. If the types of gas listed do not 
include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt 
shall be made to convert the appliance from the gas specified on the 
model/serial rating plate for use with a different gas without consulting 
the serving gas supplier. See “Gas Conversions” section.
GAS SUPPLY LINE
 ■ Provide a gas supply line of 
3
/
4
" (1.9 cm) rigid pipe to the range 
location. A smaller size pipe on longer runs may result in insufficient 
gas supply. With LP gas, piping or tubing size can be 
1
/
2
" (1.3 cm) 
minimum. Usually, LP gas suppliers determine the size and materials 
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be 
used. Do not use TEFLON
®†
 tape.
Flexible metal appliance connector:
 ■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 
152.4 cm) long, 
1
/
2
" (1.3 cm) or 
3
/
4
" (1.9 cm) I.D., flexible metal 
appliance connector may be used for connecting range to the gas 
supply line.
 ■ A 
1
/
2
" (1.3 cm) male pipe thread is needed for connection to the female 
pipe threads of the inlet to the appliance pressure regulator.
 ■ Do not kink or damage the flexible metal tubing when moving the 
range.
 ■  Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff valve. This 
valve should be located in the same room but external to the range 
opening, such as an adjacent cabinet. It should be in a location that 
allows ease of opening and closing. Do not block access to shutoff 
valve. The valve is for turning on or shutting off gas to the range.
A.  Gas supply line
B.  Shutoff valve “open” position
C.  To range
†
®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
PRODUCT DIMENSIONS
A. 27
7
/
8
" (70.8 cm) max. depth with handle
B.  36" (91.4 cm) cooktop height (max.) with leveling legs screwed all the 
way in*
C. 46
7
/
8
" (119.1 cm) overall height (max.) with leveling legs screwed all 
the way in*
D. 29
7
/
8
" (75.9 cm) width
E. 25
7
/
16
" (64.6 cm) depth. Back of range to front of cooktop**
F.  Model/serial rating plate (located on the oven frame behind the 
top left side of the oven door)
IMPORTANT: Range must be level after installation. Follow the 
instructions in the “Level Range” section. Using the cooktop as a 
reference for leveling the range is not recommended.
  * Range can be raised approximately 1" (2.5 cm) by adjusting the 
leveling legs.
 ** Front of door and drawer may extend further forward, depending on 
styling.
A
B
C
D
E
F
A
B
C