Operating Guide

16
How to set:
Press the TIMER 0.5-24 hr pad on the unit or the TIMER
pad on the remote control. Each touch of the INCREASE
S / DECREASE T pads on the unit or the INCREASE
(+) / DECREASE (-) pads on the remote control will set
the timer in 0.5 (1/2 hr.) or 1-hour intervals. (The delay
timer can be set in 0.5 (1/2 hr.) increments if programmed
for under 10 hours, but if the delay timer is set for above
10 hours, the timer will be set in 1-hour increments.)
The SET light will turn on while setting.
To review the remaining time, press the TIMER 0.5-24
hr TIMER pad on the unit or the TIMER pad on the
remote control. Use the INCREASE S / DECREASE
T pads on the unit or the INCREASE (+) / DECREASE
(-) pads on the remote control to set a new time if de-
sired.
To cancel the timer, press and hold the TIMER 0.5-24
hr pad until the light on the TIMER 0.5-24 hr pad goes
off.
u Swing Pad
Turn on to provide continuous side-to-side air circulation.
For fixed side-to-side air direction, turn on until the de-
sired air direction is obtained, then turn it off.
Remote Control:
To ensure proper operation, aim the remote control at
the signal receiver on the air conditioner.
The remote control signal has a range of up to 20 feet.
Make sure nothing is between the air conditioner and
the remote control that could block the signal.
Make sure your batteries are fresh and installed cor-
rectly as indicated on the remote control.
Cool Mode
Use the COOL mode at LOW, MED, HIGH, or AUTO
FAN SPEED for cooling. Use the TEMPERATURE IN-
CREASE S / DECREASE T pads to set the desired
temperature between 61° and 86°F in 1° increments.
The compressor will cycle on and off to keep the room at
the set level of comfort. Set the thermostat at a lower
number and the indoor air will become cooler. Set the
thermostat at a higher number and the indoor air will be-
come warmer.
NOTE: If the air conditioner is off and then turned on
while set to a COOL setting, or if it is turned from a fan
setting to a COOL setting, it may take approximately 3
minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling - Select the COOL mode and HIGH
or MED fan with a middle set temperature.
For Maximum Cooling - Select the COOL mode and
HIGH fan with a lower set temperature.
For Quieter & Nighttime Cooling - Select the COOL
mode and LOW fan with a middle set temperature.
Energy Saver Mode
Controls the fan.
ON - The fan will cycle on and off with the compressor.
This results in wider variations of room temperature
and humidity and is normally used when the room is
unoccupied.
NOTE: The fan may continue to run for a short time after
the compressor cycles off.
OFF - The fan runs all the time, while the compressor
cycles on and off.
Fan Only Mode
Use the FAN ONLY mode at LOW, MED or HIGH fan
speed to provide air circulation and filtering without cool-
ing. Since the fan only settings do not provide cooling, a
SET temperature cannot be entered. The room tempera-
ture will appear in the display.
NOTE: Auto Fan Speed cannot be used when in the FAN
ONLY mode.
Heat Mode (on some models)
Use the HEAT mode at LOW, MED, HIGH or AUTO FAN
SPEED for heating. Use the TEMPERATURE INCREASE
S / DECREASE T pads to set the desired tempera-
ture between 61°F and 86°F in 1°F increments.
Auto Fan Speed
Set to AUTO fan speed for the fan speed to automati-
cally set to the speed needed to provide optimum com-
fort settings with the set temperature. If the room needs
more cooling, the fan speed will automatically increase.
If the room needs less cooling, the fan speed will auto-
matically decrease.
NOTE: Auto Fan Speed cannot be used when in the FAN
ONLY mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will
automatically re-start in the settings last used, after the
power is restored. If the TIMER 0.5-24 hr feature was
set, it will resume countdown. You may need to set a
new time if desired.