General Operating Instructions
While operation of all units is similar, controls vary slightly
from model to model. Operating Controls section shows
control panel of unit purchased and gives detailed information
about operation of controls.
Initial Start-Up and Cooling
Select the highest fan speed and set temperature control to
its coldest position. When the desired temperature is
reached, slowly move the temperature control toward a
warmer setting until the compressor shuts off. The thermo-
stat will then cycle the compressor on and off to maintain this
selected temperature. Adjust the fan speed for desired air
circulation.
OUTDOOR
LOUVERS
INDOOR
GRILLE
BAFF LES
Changing Airflow Direction Baffles
Airflow on unit may be diverted left or right from center by
baffles. Upward and downward air discharge is provided by
tilting louvers. Adjust baffles and tilt louvers for desired
airflow pattern.
Airflow Around Unit
Check the indoor grille and outdoor louvers for obstructions to
airflow. Do not block the airflow to and from the unit. If air is
obstructed and/or deflected back into the unit, the air
conditioner’s compressor may cycle on and off rapidly. This
could damage your unit.
Drain Cup Installation and Use (on some models)
Your air conditioner uses a system where the water removed
from the indoor air (condensate) is channeled to the outdoor
side of the unit. The outdoor fan blade has a “slinger” ring
attached to it that dips into the water and slings the water
onto the outdoor coil surface. This is the sound of water you
hear during normal operation. The water quickly evaporates
on this warm surface and improves the efficiency of your air
conditioner. In normal conditions the unit can evaporate the
water as fast as it is removed from the indoor air.
However, in very humid conditions excess amounts of water
may drip off the unit chassis. If this proves to be a problem,
install the condensate drain cup included with the unit to
route excess water where it would not be a problem (see
illustration below).
To install, remove the unit chassis from the outer case. Insert
the condensate drain cup through the recessed ½” hole on
the back center flange of the outer case. Once inserted,
place a ½” diameter hose or tube on the drain cup bottom
spout. The hose allows you to route where you want the
excess water to go. Reinsert the unit chassis into the outer
case. The unit basepan overflow hole will be positioned
directly above the drain cup and will catch any water that
might run out.
1/2" Diameter
Hose
Condensate
Drain Cup
Outer Case