User`s guide
SA-PCR PRO.11 PC Card Installation, Setup, and Management
User’s Guide
4-18
BreezeNET PRO.11 Series
The Configuration Access tab displays the current mode (User, Installer, or
Technician) in the Present Mode box. This mode determines the security access to
system parameters. Users can view some of the window tabs, but cannot modify
parameters. Installers can view all of the tabs and can modify some of the values.
Technician access rights are reserved for certified BreezeCOM technicians.
When the Configuration utility opens, it will begin at the same mode that was active
when it closed. If security is an issue, change the access mode to User before you
close the utility. The first time the utility is opened, it is set to Installer access mode.
The default password for Installer mode is User, however you can change this
password If security considerations play an important role in the construction of
your WLAN.
⇒
To change the Configuration Access mode:
1. Select the radio button next to the desired mode.
2. Type in the password. No password is necessary to lower the access right level.
3. Click Set mode. The name of the new mode appears in the Present Mode box.
⇒
To change the password for Installer Configuration Access mode:
1. Look at the Present Mode box to verify that you are in Installer mode.
2. Click Change Password.
3. In the Change Password dialog box, type in the new password twice and click
OK. The BreezeNET Monitor changes your password.
Note: If you change the Installer password do not forget it, or you will be unable to
change the unit's access rights.