User`s guide
Using the Local Terminal for Unit Setup and Management
User’s Guide
3-16
BreezeNET PRO.11 Series
• P.S. Broadcast Reservation Percentage – Determines the buffer space
reserved for broadcast frames in percentages. Default value is 30% ( Auto
storing - no reservation). Allowed range is 0%-30%.
Note: It is recommended to leave it at default setting.
3.5.3 Radio
The Radio menu contains the following parameters:
• Hopping Standard – The Hopping Standard is a set of rules regarding the
radio transmission standard allowed in each country. Units will work together
only if set to the same hopping standard. Use this parameter to set the unit’s
hopping standard to that of the relevant country.
• Power level – Output power level at which the unit is transmitting. There are
two possibilities, Low (4dBm) or High (17 dBm) at the antenna connector.
3.5.4 Rate
• Multi-Rate Support – When this parameter is enabled, the unit will
automatically switch to the best transmission rate at any given time. When the
parameter is disabled, the unit will always stay at the maximum rate
configured in the WLAN Parameters menu.
3.5.5 AP Redundancy Support
When the AP identifies that the Ethernet link has been discontinued over a defined
period of time, it then stops transmitting and forces the stations associated with it to
associate with another AP.
The default mode for the AP Redundancy Support parameter is disabled (the AP
continues transmitting even when the ETH link is discontinued). This can only be
configured by a Technician. It is recommended to use this parameter only when
more than one AP is connected to the same distribution system and this AP is
configured to the same ESSID.