User`s guide

Using the Local Terminal for Unit Setup and Management
User’s Guide
3-8
BreezeNET PRO.11 Series
frequency to frequency according to the selected sequence. When more than
one AP is co-located in the same area (even if they are not part of the same
network) it is recommended to assign a different hopping sequence to each AP.
Hopping sequences are grouped in three hopping sets (see the following
parameter). When setting up multiple APs in the same site, always choose
hopping sequences from the same hopping set. This reduces the possibility of
collisions on the WLAN.
This parameter is set only for the BreezeNET PRO.11 Access Point. It is not
accessible from any other BreezeNET PRO.11 unit. During the association
process, all other stations learn the hopping sequence from the Access Point.
Different co-located WLAN segments should use different hopping sequences.
Hopping Set (AP Only) – Hopping set (between 1 and 3) of the unit. Hopping
sequences are grouped in several hopping sets. Always use the same hopping
set per site.
The number of hopping sequences per set is different for each hopping standard
according to the following table:
Table 3-1. Hopping Sequences
Hopping Standard Number of Sequences
per Hopping Set
Netherlands 5
Europe ETSI 26
France 11
US FCC 26
Japan 4
Australia 20
Israel 11
Canada 10
Europe ETSI (DE Model) 10
Korea 4
Spain 9