System Intervals
To display the system interval parameters to monitor the Base Station, you must
first connect to the target Base Station as described in Connecting to Base
Stations.
Select the
System tab and click the Options button to display the window
pictured in Figure 5-22.
Figure 5-22: Intervals window
In the Intervals window two different time interval parameters can be set to
change to monitor interval settings:
! Analysis polling interval (used for remote link test)
! SNMP polling interval (used for SNMP statistics)
Adjusting Analysis Polling Interval
Subject to the type of connection, you can adjust the refresh rate of the remote
link test results, also identified as the analysis polling interval.
While the remote link test will proceed to continuously collect measurement
results, the selected Base Station (initiator station) will transfer the results to
the LAN administrator station at regular intervals, which can vary from 1 to 15
seconds.
! Use a short time interval (e.g.1 second) for on-line monitoring, e.g., when
troubleshooting or when you have full bandwidth access via the local
network.
! Use a longer time interval (e.g. 15 seconds) when you run a remote link
test only for background information purposes, or in cases when you access