User guide
Monitoring Your BreezeNET Network
5-17
Alvarion
2. Enter a filename for your log file in the field Log Filename.
If you:
! Enter a new filename - a new file is created.
! Enter the same filename - the data will be appended
! Use the default filename - the data will be appended.
3. Select the mode of logging:
! Data logging off - no data is logged.
! Manual data logging - to manually record your link measurements.
Optionally, you can add comments each time you log data by clicking
the “Add comments” check box.
! Automatic data logging - to automatically log data. You must enter a
time interval between measurements.
! Continuous data logging (only available in Link Test window) -
Automatically log data with the following interval:
" Once per second, or
" Once per minute
In all modes, the measurement data is saved in the file entered in the
Log
Filename
field. Each time new data is saved, this information is appended to the
existing file. If you wish to save the data in a new file, use this field to enter a
new filename.
Starting/Stopping the Logging Function
Depending on your choice of logging option, the logging button will read either
Log Once (manual option) or Start Log (automatic options).
! For manual logging, click the “Log Once” button each time you wish to log
data. Logging stops automatically after the data is recorded to the log file.
! For automatic logging, click the
Start Log button. Click the Stop Log button
to stop the logging function.
Diagnose Card
If you suspect that your wireless client adapter may not be functioning properly,
you can select
Diagnostics in the Advanced menu of the main Client Manager
window to investigate the functionality of the hardware and software of the
card.
The Diagnose Card window allows you to check the software and firmware
information, configuration information as well as communication statistics.
To test the wireless client adapter, click the
Test Card Now button on the Card
Check
tab.