User guide

Appendix C
C-7
Alvarion
You are advised to check the configuration settings. Click Ok to
continue.
! If you do not have a back-up configuration file, or if you do have a file
but do not want to use this file to configure the Base Station click
No.
You are now advised to manually modify/verify the configuration
settings of the Base Station (i.e. assign a unique IP address, setup the
BreezeNET parameters and, (if applicable) the other Base Station
identifiers such as the IP Address and SNMP passwords).
7. The Edit Configuration window is displayed. Note that the Edit
Configuration window does not contain an
OK button but an Upload button
to upload the configuration settings to the Base Station.This means that you
are editing a local configuration file and that you are not yet connected to the
Base Station.
8. View (and modify) the configuration settings in all tabs.
Refer to Chapter 4 “Basic Network Configuration” for changing the
configuration settings.
9. Click the
Upload button to upload the new configuration settings to the Base
Station in force reload mode.
The message “Please wait while trying to connect to the Base Station”
appears. While trying to connect to the Base Station, the IP address in the
configuration settings is pinged.
! Only if the IP address specified in the configuration already exists, you
are prompted to enter a new IP address. If the IP address does not yet
exists the uploading continues.
! Because the password of the Base Station in forced reload mode is
always “public”, you do not have to enter this password before
uploading information to the Base Station.
10.When prompted to confirm the “Reload of the Remote System”, click
Yes
to continue.
The local software file (“wpntxxx.bin” or “ap05xxx.bin”) will now import
the configuration settings and save these to the software (binary) file. The
software file will now be overwritten by the new software file. This does
not influence the functionality of the software file. For more information
see Upload Software, a Look under the Hood on page D-3.
When you want to preserve the original software file, make a back-up copy
of this file.
11.You are again prompted to confirm the “Reload of the Remote System”.
Check the list of parameters displayed thoroughly to make sure all settings
are right.