Table B-11 :LED Error Table
Power Ethernet Wireless
interface
A
Description/Action:
Continuous
Green
Flicker
Green
Flicker
Green
Normal operation where flickering
indicates interface activity.
No action required.
Off Off Normal operation that indicates there is no
LAN activity
No action required
(Optional) Check if all ethernet
connections are properly installed
Off Off Off No power.
Check the power cord,
Check the power supply
Continuous
Green
Flicker
Green
Amber Network overload.
The ethernet connection sends more traffic
to wireless stations than the Base Station
Bridge can forward to the interface
1
.
Run the AP Manager Remote Statistics to
investigate network performance.
If possible try to eliminate redundant
traffic by:
Filtering protocols
Setting storm threshold, or
Shut down defect ethernet stations that
transmit excessive data
1. When traffic load exceeds the wireless throughput capacity (>11MB/s), the Base Station will buffer such
requests. In this situation however the buffer is full, and packets are ignored.
-
Green Amber
Continuous
Green
Flash
Red
- Frames are rejected because of an
unknown cause.
Run the AP Manager Remote Statistics to
investigate the number of packets in error.
If this number is relatively high, run a
remote link test to determine which station
is causing the packet loss.
-Flash Red
-
Power Ethernet Wireless
interface
A
Description/Action:
Amber Off Off Forced reload state.
Proceed with the forced reload procedure as
described in Appendix C: Forced Reload
Procedure on page C-1 of this user’s guide.
Amber Amber
A