User guide

8-10
BreezeNET DS.11b User’s Guide
Manual Version 1.0
The mandatory parameters that you must specify are:
! Base Station
“IP address” (unique for each Base Station, in case of a
BOOTP or DHCP server, this IP address is entered automatically).
! Base Station
“Subnet Mask” (the same for all Base Stations, in case of a
BOOTP or DHCP server, this IP address is entered automatically).
! (optional)
Default router (usually the same for all Base Stations).
! (optional)
Default TTL (Time To Live) (usually the same for all Base
Stations).
All parameters are explained in the next paragraphs.
3. When finished, proceed with configuring other parameters or click
OK to
save the configuration and return to the main AP Manager window.
Figure 8-40
: Setup Base Station IP Parameters
IP address
Each Base Station needs an unique IP address. Use either:
! DHCP, to obtain an IP address automatically, or
! manually enter an IP address
Manually assign an IP address
In case of manually assigning an IP address, use the field Base Station
IP Address
to enter a value from the range of IP addresses assigned to your organization.
NOTE:
All Base Stations must have a unique IP address value to allow you to address each Base
Station specifically. Duplicate IP address values may cause unexpected behavior of the
network and/or negative impact on network performance.