Programming instructions

Appendix B:
Preparing the
Indoor to Outdoor
Cable
The Indoor-to-Outdoor cable provides pin-to-pin connection on both
sides. It is supplied open-ended at both sides, to allow the installer to
conveniently route the cable into the waterproof seal off the Outdoor
unit and through holes in walls.
Figure B-1 shows the wire pair connections required for the Indoor-to-
Outdoor cable.
Figure B-1: Ethernet Connector Pin Assignments
Use a crimp tool for RJ-45 connectors to prepare the wires, insert them
into the appropriate pins and use the crimp tool to crimp the connector.
Make sure to do the following:
! Remove as small a length as possible of the external jacket. Verify
that the external jacket is well inside the service box to ensure good
sealing.
! Take back the shield drain wire before inserting the cable into the
RJ-45 connector, to ensure a good connection with the connector’s
shield after crimping.