Programming instructions
2-16
BreezeNET DS.5800 System Manual
Manual Revision: 1.0
Table 2-4: Outdoor Unit LEDs
What to do if the Self Test fails
If the Self-Test failed (DC Power LED light remains red), try the
following:
! Reset unit (Disconnect/reconnect the power).
! Check the Indoor-to-Outdoor cable.
! Reset to factory defaults (see page 47).
! Contact technical support.
Name Description Functionality
WLAN Wireless Link Indicator Blinking Green – Data received or transmitted
on the wireless link. Blinking rate is slower
when there is less wireless traffic.
DC Power Self Test and Power
indication
Green – Power is available and self test passed.
Red – Self test failed. Firmware did not load
successfully.
ETH Ethernet activity/
connectivity indication
OFF –Ethernet connectivity is OK.
No traffic activity detected on the port.
Blinking Green –Ethernet connectivity is OK,
with traffic on the port.
Red – No Ethernet connectivity. When this
state occurs, check the Ethernet cable and
Indoor-to-Outdoor cable connections.
RSSI BAR RB-DS.5800: Received Signal Strength
Indication
BU-DS.5800: Number of associated
RB-DS.5800 units