Programming instructions

2-12
BreezeNET DS.5800 System Manual
Manual Revision: 1.0
Installing the Indoor Unit
Route the Indoor-to-Outdoor cable into the building so that it
conveniently reaches the indoor unit while avoiding interference
sources. It is recommended that the cable be a little longer then
necessary. The cable is supplied open ended so it can be conveniently
threaded as shown into the building.
1. Remove the wall-mounting bracket clipped to the back of the indoor
unit and mount it on a wall as shown in Figure 2-5. Mount the
indoor unit on the mounting bracket.
2. Assemble an RJ-45 connector with a protective cover on the indoor
side of the Indoor-to-Outdoor cable. Refer to Appendix B for
instructions on preparing the RJ-45 cable connector.
3. Connect the Indoor-to-Outdoor cable to the Radio connector, located
on the top panel of the indoor unit shown in Figure 2-7. The Indoor-
to-Outdoor cable should be connected to the unit before the unit is
connected to the mains power.
Figure 2-5: Wall Mounting the Indoor Unit
NOTE:
The color codes of the power cable are:
brown = phase ~
blue = neutral 0
yellow/green = grounding