4-4
Problem and
Indication
Possible Cause Corrective Action
Wireless link
established, but
there is no
Ethernet activity
(BU-DS.11 and
RB-DS.11 units).
1. Ethernet hub port or
UTP cable is faulty.
2. Ethernet port in unit
is faulty.
3. The RB-DS.11 is
associated to a
BU-DS.11 unit that is
not connected correctly
to the LAN.
1. Check that the LINK LED is lighted
Green. If this is not the case, the port is
inactive. Try another port on the hub or
another UTP cable.
2. Verify that Ethernet port in unit is
working. Ping unit to verify Ethernet
connection.
3. Verify that you are using a cross-over
UTP cable (pins 1 & 3, 2 & 6) if
connected directly to a workstation, or a
straight-through cable if connected to a
hub.
4. Check the unit’s LINK LED indicator
and check the Ethernet counters in the
monitor to verify Ethernet activity.
5. Check that the BU-DS.11 is correctly
connected to the LAN.