User`s guide

BreezeNET DS.11 Series User’s Guide
4-2
Troubleshooting Guide
Problem and
Indication
Possible Cause Corrective Action
No power to unit.
Power LED is off.
Power cord is not
properly connected.
Verify power cord is properly connected
to the BreezeNET unit and to the power
outlet.
Failure to
establish wireless
link. WIRELESS
LINK LED is off
and unit resets
every few
minutes.
1. Power supply to units
may be faulty
2. The RB-DS.11 units
may not have the same
ESSID as the BU-
DS.11.
1. Verify power to units.
2. Verify that all units in the network have
the same ESSID (ESSID must be
identical in all units in the WLAN; the
ESSID is case sensitive). Check that the
units are on the same channel.
3. Verify wireless link:
Set BU-DS.11 and RB-DS.11 units side
by side.
Power on each unit and see if a wireless
link is established (even “D” models
without their external antennas should
establish a link if placed side by side).
If the units fail to associate, reset units to
factory default values. The units should
now establish a wireless link.