Verifying Correct Operation
The following sections describe how to ensure that the units
are correctly installed and functioning properly.
Verifying Correct Operation of
the Indoor Unit
To verify proper operation, check the LED indicators located
on the top panel of the indoor unit as shown in Figure 2-6 on
page 2-20, and as described in Table 2-2.
Name Description Functionality
POWER
Power indication Green - 48VDC is present on the Radio RJ45
port.
Off - No power is supplied to the Radio RJ45
port.
LINK
Self Test and Ethernet
Link indication
The LINK LED indicates end-to-end
connection between the outdoor unit and the
Ethernet connection to the indoor unit.
Off – No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit.
Orange– Self-test passed and Ethernet
connection is confirmed by the Outdoor unit
(Ethernet integrity check passed).