Specifications
Chapter 3 - Commissioning Configuring Basic Parameters
BreezeNET B 38 System Manual
3.1.2 Country Code Selection
3.1.3 Transmit Power Compliance With Regulations
Maximum Link Distance (BU) 0 (No Compensation)
Maximum Modulation Level 8 (or the highest value supported
according to the country code).
Refer to
Section 3.4
Wi2 IP Address (RB) 0.0.0.0 (none)
VLAN ID-Management 65535
Authentication Algorithm Open System Availability of security parameters
depends on support according to
the Country Code.
Data Encryption Option Disable
Security Mode WEP
Default Key (RB) Key 1
Key 1 to Key 4 00……0 (32 zeros, meaning no key)
NOTE
Some parameters are changed to their new values only after reset (refer to Appendix E for more
details). After the basic parameters are configured, the unit should be reset in order to activate the
new configuration.
CAUTION
The selected Country Code must comply with applicable local radio regulations.
CAUTION
In regions where local radio regulations limit the maximum transmit power of the unit the installer is
responsible to properly set the Antenna Gain parameter (if configurable) according to the actual
antenna being used. This will limit the upper limits of the Tx Power parameter in the BU and the
Maximum Tx Power in the RB (where applicable) to the value of "Permitted EIRP-Antenna Gain".
The Tx Power parameter in the BU and the Maximum Tx Power in the RB (where applicable) should
not exceed the Permitted EIRP-Antenna Gain, according to the following table:
Table 3-1: Basic Parameters
Parameter Default Value Comment