Specifications
Chapter 3 - Commissioning Configuring Basic Parameters
BreezeNET B 37 System Manual
Hidden ESSID Option (BU) Disable
Hidden ESSID Support (RB) Disable
Operator ESSID Option (BU) Enable
Operator ESSID (BU) ESSID1 Applicable only if Operator ESSID
Option is set to Enable.
Country Code Select Depends on factory configuration Applicable only for 5.4 and 5.8 GHz
units. See
Section 3.1.2 below.
Sub Band Select (BU) 1 Applicable only if more than one
Sub Band is available.
Frequency (BU) The lowest frequency in the
selected Sub Band
User Defined Frequency Subsets
(RB)
A (All) The list of frequencies is in
accordance with the Sub Band.
DFS Required By Regulation (if
DFS is supported by Country Code)
Depends on Country Code
Frequency Subset Definition (BU, if
DFS is supported)
All frequencies Applicable only if DFS is enabled
DFS Detection Algorithm (for
Universal Country Code in 5.4 or 5.8
GHz band)
ETSI Applicable only if DFS is enabled
Transmit Power Dependent on unit type and Sub
Band
Transmit Power in RB cannot be
higher than the Maximum Tx Power
parameter
Maximum Tx Power (RB) Dependent on Sub Band Maximum Tx Power cannot be
higher than the upper limit
according to the Sub Band in use.
Tx Control (BU) On
Antenna Gain Depends on unit type and Sub Band If set to "Not Set Yet", must be
configured according to actual
value, taking into account cable's
attenuation.
ATPC Option Enable
Best BU Support (RB) Disable
Preferred BU MAC Address (RB) 00-00-00-00-00-00 (none) Applicable only when Best BU
Support is enabled
Link Distance Mode (BU) Automatic
Table 3-1: Basic Parameters
Parameter Default Value Comment