Specifications
Chapter 3 - Commissioning Configuring Basic Parameters
BreezeNET B 36 System Manual
3.1 Configuring Basic Parameters
3.1.1 Initial Configuration
After completing the installation process, as described in the preceding chapter,
the basic parameters must be configured to ensure that the unit operates
correctly. After the basic parameters have been configured, additional parameters
can be remotely configured via the Ethernet port or the wireless link using Telnet
or SNMP-based management, or by loading a configuration file.
Refer to Section 4.1 for information on how to access the Monitor program using
Telnet.
The Basic Configuration menu in the Monitor program includes all the parameters
necessary for the initial installation and operation of BreezeNET B units. In many
installations, most of these parameters should not be changed from their default
values. The basic parameters and their default values are listed in Table 3-1.
Refer to Section 4.2 for detailed information on the applicable parameters.
NOTE
For compliance with ETSI regulations, the bandwidth used in the default Sub Band for units in the
5.4 GHz band is 20 MHz. The use of a Sub Band with a 40 MHz bandwidth (Turbo Mode) in the 5.4
GHz band is allowed only if approved by the applicable local regulatory administration.
Table 3-1: Basic Parameters
Parameter Default Value Comment
Change Unit Type to RB (in Unit
Control Menu)
If necessary.
Reset before continuing with
configuration.
Ethernet Port Negotiation Mode (in
Unit Control Parameters)
Auto Negotiation
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Options Disable
Access to DHCP BU: From Ethernet Only
RB: From Wireless Only
ESSID ESSID1