Specifications

Chapter 2 - Installation Installation Requirements
BreezeNET B 17 System Manual
Mains plug adapter or termination plug (if the power plug on the supplied AC
power cord does not fit local power outlets)
Portable PC with Ethernet card and AlvariCRAFT * application and a crossed
Ethernet cable
Installation tools and materials, including appropriate means (e.g. a pole) for
installing the outdoor equipment.
2.1.1.2 Optional Items*
Tilt Pole Mounting kit for the smaller size ODU of BU/RB-B10 units
A Y-cable for connecting directly to the IDU COM of the BU/RB-B10 ODU for
configuration/performance monitoring using a portable PC.
2.1.2 Indoor-to-Outdoor Cables
Use only Category 5E Ethernet cables from approved manufacturers, listed in
Table 2-1. Consult with Alvarion's specialists on the suitability of other cables.
NOTE
Items marked with an asterisk (*) are available from Alvarion.
NOTE
The length of the Indoor-to-Outdoor Ethernet cable should not exceed 90 meters. The length of the
Ethernet cable connecting the indoor unit to the user's equipment, together with the length of the
Indoor-to-Outdoor cable, should not exceed 100 meters.
Table 2-1: Approved Category 5E Ethernet Cables
Manufacturer Part Number
Synergy Cables Ltd.
www.synergy-cables.com
612098
HES Cabling Systems
www.hescs.com
H5E-00481