Specifications

Appendix E - Parameters Summary Parameters Summary
BreezeNET B 199 System Manual
Antenna Gain*** BU, RB Minimum: 0 (dBi)
Maximum: 50 or Regulation Max
EIRP+10 (the lower of the two
values).
"Don't Care" or
"Not Set Yet" or 21
(depending on unit
type and
regulations)
No
Spectrum Analysis
Channel Scan Period
BU, RB 2 - 30 seconds 5 seconds Yes
(Configured
per analysis)
Spectrum Analysis
Scan Cycles
BU, RB 1 - 100 cycles 2 cycles Yes
(Configured
per analysis)
Automatic Channel
Selection
BU
Disable
Enable
Disable Yes
(Configured
per analysis)
Lost Beacons
Watchdog Threshold
BU 100 - 1000, 0 means Not Used 218 Yes
Noise Immunity State
Control
BU, RB
Automatic
Manual
Automatic Yes
Noise Immunity Level BU, RB 0 - 4
Use only 0 or 4
0Yes
Spur Immunity Level BU, RB 0 - 7 0 Yes
OFDM Weak Signal BU, RB 0 (not active) or 1 (active) 0 Yes
Pulse Detection
Sensitivity
BU, RB
Low
High
Low Yes
Noise Floor Calculation
Mode
BU, RB
Fully Automatic
Forced
Automatic with Minimum Value
Fully Automatic Yes
Noise Floor Forced
Value
BU, RB -107 to -55 (dBm) 10 MHz bandwidth:
-99
20 MHz bandwidth:
-96
40 MHz bandwidth:
-93
Yes
Parameter Unit Range Default Run-Time