Specifications

Chapter 4 - Operation Menus and Parameters
BreezeNET B 80 System Manual
MAC Address Database
Link Quality (RB only)
Hidden ESSID Table (RB only)
Continuous Noise Floor Display (BU only)
Per Modulation Level Counters
Link Capability
4.2.5.1 Traffic Statistics
The traffic statistics are used to monitor, interpret and analyze the performance of
the wired and wireless links. The counters display statistics relating to wireless
link and Ethernet frames. The Traffic Statistics menu includes the following
options:
Display Counters: Select this option to display the current value of the
Ethernet and wireless link (WLAN) counters.
Reset Counters: Select this option to reset the counters.
4.2.5.1.1 Ethernet Counters
The unit receives Ethernet frames from its Ethernet port and forwards the frames
to its internal bridge, which determines whether each frame should be
transmitted to the wireless media. Frames discarded by the unit's hardware filter
are not counted by the Ethernet counters. For B14/B28 units the maximum
length of a regular IEEE 802.1 Ethernet packet that can be accepted from or
transmitted to the Ethernet port is 1514 bytes, excluding VLAN and CRC. For
B100 units the maximum length of an Ethernet packet that can be accepted from
or transmitted to the Ethernet port (excluding CRC) is 1600 bytes, including
VLAN.
The unit transmits valid data frames received from the wireless media to the
Ethernet port, as well as internally generated frames, such as responses to
management queries and pings received via the Ethernet port. The Ethernet
Counters include the following statistics:
Total received frames via Ethernet: The total number of frames received from
the Ethernet port. This counter includes both invalid frames (with errors) and
valid frames (without errors).