Instruction manual
4-4
BreezeACCESS Version 4.3 Commissioning
Manual Revision: 4.0
LED Indicators
To verify correct operation of the units, view the status of the relevant
LED indicators:
SU-RA/RE Outdoor Units LEDs
Table 4-1: SU-RA/RE Outdoor Units LEDs
AU-RE Outdoor Units LEDs
Table 4-2: AU-RE Outdoor Units LEDs
Name Description Functionality
ALARM Alarm
indication
On – A problem with the power amplifier or in the locking
process of any of the synthesizers
Off – Normal operation
WLNK Wireless link
activity
Blinking – Receiving packet from the wireless link
Off – No reception of packets from the wireless link
ETH Ethernet
activity
Blinking – Data received from or transmitted to Ethernet LAN
Off – No activity on the Ethernet LAN
Name Description Functionality
ALARM Alarm
indication
On – A problem with the power amplifier or in the locking
process of any of the synthesizers
Off –Normal operation
12V IN 12 VDC Power
Indication
On – 12 VDC power is supplied to the unit
Off – 12 VDC power is not available
ETH Ethernet
activity
Blinking – Data received from or transmitted to Ethernet
LAN
Off – No activity on the Ethernet LAN