Instruction manual

Connecting External Alarm Devices
3-3
BreezeACCESS Version 4.3 System Manual
Alarms Out Cable
Table 3-2: Alarms Out Cable
GPS Cable
Cable Type: EIA RS-422 3X2X25AWG +1X2X24 AWG FTP Shielded
cable.
Table 3-3: GPS Cable
9-pin Micro D-Type
AL OUT Connector
Description Color Code
1 Relay 1 Common Brown
2 Relay 1 Normally Closed White
3 Relay 2 Common Green
4 Relay 3 Common Red
5 Relay 3 Normally Closed Black
6 Relay 1 Normally Open Purple
7 Relay 2 Normally Closed Yellow
8 Relay 2 Normally Open Orange
9 Relay 3 Normally Open Blue
NOTE:
The other side of the cable is supplied open-ended. The cable shield is
connected to the body of the connector.
9-pin Micro D-Type
SYNC IN Connector
Description* Color Code
12-pin Round
Connector
1GPS TX+Yellow5
2 GPS TX- Green 4
3GPS RX+Red3
4GPS RX-Orange2
5 1PPS+ Brown 11
6 1PPS- Black 12
7 DC GPS+ Blue (thick) 1
8 DC GPS- Brown (thick) 9
9 Not connected ---- 6,7,8,10