Instruction manual
3-2
BreezeACCESS Version 4.3 Commissioning
Manual Revision: 4.0
Connecting External Devices
to the BS-GU AL IN and/or AL
OUT Connectors
Open-ended cables are available from the company for connecting to the
module external alarm inputs through the AL IN connector and/or
activating external devices through the AL OUT connector. See the
tables that follow for descriptions of the connectors’ pins functionality.
For details on defining and using the alarm inputs and output, refer to
Book 4: Operation and Administration.
Alarms In Cable
Table 3-1: Alarms In Cable
WARNING:
The load of the Alarm Out (AL OUT) connector should not exceed 24 V@1 A max.
9-pin Micro D-Type
AL IN Connector
Description Color Code
1 Alarm Input 1 Brown
2 Alarm Input 2 White
3 Alarm Input 3 Green
4 Alarm Input 4 Red
5 Not Connected Black
6GNDPurple
7 GND Yellow
8GNDOrange
9GNDBlue
NOTE: