Instruction manual

Setting Basic Parameters
1-7
BreezeACCESS Version 4.3 System Manual
Configuring Parameters in
GU-A-BS Units
Introduction
This section describes all the parameters that are necessary for the
initial installation and operation of GU-A-BS units. Once the unit is
properly installed and operational, other parameters can be configured
using the monitor program via Telnet or SNMP management.
Since all the parameters needed are found in the Advanced
Configuration menu, Administrator level access is required in order to
configure a GU-A-BS unit.
Refer to Book 4: Operation and Administration for detailed information
on the applicable parameters.
In many installations, most of these parameters should not be changed
from their default values. The following list includes the basic
parameters and their default values:
Table 1-6: GU-A-BS Units Basic Parameters
Once the basic parameters are configured, the unit must be reset in
order to activate the new configuration.
NOTE:
The BS-GU does not have an external MON port, and therefore must be configured
using Telnet.
Parameter Default Value Comment
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Option Disable
Number of Hopping
Frequencies
According to the Number of
Hopping Frequencies in the AUs
Automatic Recovery Option Disable Not Applicable to “slave”
modules.
VLAN ID – Management 65535