Instruction manual

Setting Basic Parameters
1-5
BreezeACCESS Version 4.3 System Manual
Configuring Basic Parameters
in Access and Subscriber
Units
The Basic Configuration menu in the Monitor program includes all the
parameters necessary for the initial operation of BreezeACCESS
Subscriber and Access Units. In many installations, most of these
parameters should not be changed from their default values. The
following list includes the basic parameters and their default values:
Table 1-3: Subscriber and Access Units Basic Parameters:
Parameter Default Value Comment
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Option Disable
Access to DHCP AU: From Ethernet Only
SU: From Wlan Only
Hopping Band
(5.7 GHz Products only)
ISM US FCC In some units this parameter
cannot be changed for
compliance with local
regulations
Frequency Offset
(5.7 GHz products in ISM US
FCC or ISM international mode
only)
0
Flexible Hopping Definition –
Add/Remove Frequencies
In 5.7 GHz products,
applicable only if Hopping Band
is set to “Flexible Hopping
Definition”.
Scrambling Mode Standard Scrambling
Manual Sequence Definition None Applicable only if Scrambling
Mode is set to Manual
Scrambling
Spanning Factor (AU) 1 Applicable only if Scrambling
Mode is set to Enhanced
Scrambling
Hopping Shift (AU) 1