BreezeACCESS Version 4.3 Commissioning
Manual Revision: 4.0
Table 1-2: Required Type of Ethernet Cable
2. The Select Access Level menu appears. Select the access level according to
your authorized access rights. You will be requested to enter your
password. After entering the correct password press Enter. Default
passwords are listed in Table 1-1‚ page 1-2
.
3. The Main Menu appears. Proceed as you would after connecting via the
MON port.
Operating the Monitor Program
1. Type an option number to open/activate the option. You may need to press
Enter in some cases.
2. Press Esc to exit a menu or option.
3. You can log-out and exit the monitor program from the Main Menu by
selecting X (exit). (To get to the Main Menu from anywhere in the program,
press the Esc key several times). You can also exit the monitor program
from anywhere in the program by simultaneously pressing the Ctrl and X
keys.
4. Reset the unit after making configuration changes for the new values to take
effect.
Unit Type
Connection to a
PC
Connection to a
Hub
Subscriber Units Straight Crossed
Access Units Crossed Straight
GPS module Straight Crossed
NOTE:
The program will terminate automatically after a given period of inactivity specified by
the Log-Out Timer parameter.