Instruction manual

1-2
BreezeACCESS Version 4.3 Commissioning
Manual Revision: 4.0
Accessing the Monitor
Program
Accessing the Monitor Program
using the RS 232 MON Connector
1. Use the monitor cable to connect the MON connector of the unit to the COM
port of your ASCII ANSI terminal or PC. The COM port connector on the
monitor cable is a 9-pin D-type plug.
2. Run a terminal emulation program (such as HyperTerminal™).
3. Set the communication parameters as follows:
4. Press Enter. The Select Access Level menu appears. Select the access level
according to your authorized access level. You will be requested to enter
your password. After entering the correct password, press Enter.
Table 1-1‚ page 1-2 lists the default passwords for each of the access
levels.
Table 1-1: Default Passwords
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Flow Control Xon/Xoff
Connector Connected COM port
Access Rights Password
Read Only public
Installer user
Administrator private
NOTE:
Following three unsuccessful login attempts (using incorrect passwords) from either the
monitor port or via Telnet, the monitor program will be blocked for five minutes. To
access the monitor program during this time, the unit must be reset (via SNMP or by
disconnecting/reconnecting power).