Instruction manual

3-4
BreezeACCESS Version 4.3 System Description
Manual Revision: 4.0
Telephony (Subscriber Units with
voice support)
IF Indoor – Outdoor Communication
(SU-A/E, AU-E-NI, AU-E-BS)
Configuration and Management
Parameter Value
Call Progress Tones Selectable per country standard or user definable
Line Type Loop Start
On-hook Voltage -48 V
Ringer Voltage Min. 50 V r.m.s. unbalanced
Ringer Frequency Selectable: 17, 20, 25, 50 Hz
REN Max. 2
Off-hook DC current 30mA
Off-hook impedance 600 ohm or complex
Maximum input level +3 dBm
Cable length Max. 300 m, 26 AWG
Parameter Value
IF Frequency 440 MHz
IF Cable Impedance 50 ohm
Maximum IF Cable Attenuation 15 dB
Maximum IF Cable DC Resistance 1.5 ohm
Parameter Value
Management Options a. Via the MON port, using terminal emulation with the built-in
monitor program
b. Telnet, using the monitor program
c. TFTP, using the Configuration upload/download utility
d. SNMP
Remote Management Access From Wired LAN, Wireless Link
Management Access
Protection
a. Multilevel password
b. Configuration of remote access direction (from Ethernet only,
from wireless link only or from both sides)
c. Configuration of IP addresses of authorized stations
SNMP Agents SNMP ver 1 client.
MIB II, Bridge MIB, Private BreezeACCESS MIB