Site Survey Parameters
Parameter Unit Range Default
Run-
Time
Updated
RSSI Display
Option
AU, SU RSSI, dBm RSSI Yes
AU Alarms
Option
IF-based AU Disable, Enable Disable Yes
Learning Period IF-based AU 1 – 1440 (minutes) 30 (minutes) Yes
Test Cycle IF-based AU 1 – 1440 (minutes) 10 (minutes) Yes
Retransmissions
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 20 (%) Yes
Retransmissions
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 30 (%) Yes
Retransmissions
Major Alarm
Threshold
IF-based AU 1 – 100 (%) 60 (%) Yes
Dropped Frames
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 10 (%) Yes
Dropped Frames
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 10 (%) Yes
Dropped Frames
Major alarm
Threshold
IF-based AU 1 – 100 (%) 20 (%) Yes
CRC Error
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 20 (%) Yes
CRC Error
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 40 (%) Yes
CRC Error
Major Alarm
Threshold
IF-based AU 1 – 100 (%) 70 (%) Yes