Instruction manual
C-36
BreezeACCESS Version 4.3 System Manual
Manual Revision: 4.0
IP Parameters
System Information Parameters
MIB Parameter
(Location in
Parenthesis)
Description Values/Range
*IpParams
710.3.3. 11
(brzAccessMib 11)
*UnitIpAddress
710.3.3. 11.1
(*IpParams 1)
Applicable to all products. IP address of the unit. IP address
*SubNetMask
710.3.3. 11.2
(*IpParams 2)
Applicable to all products. Subnet mask of the unit. IP address
*DefaultGWAddress
710.3.3. 11.3
(*IpParams 3)
Applicable to all products. Default gateway IP address of the
unit.
IP address
*UseDhcp
710.3.3. 11.4
(*IpParams 4)
Applicable to all products. DHCP client mode of operation.
disabled: Use regular (manual) methods to configure IP
parameters.
dHCP Only: Use DHCP server to configure IP parameters.
automatic: Use DHCP server to configure IP parameters. If a
DHCP server is not available, use configured values for
*UnitIpAddress, *SubNetMask and *DefaultGWAddress.
Integer
disable (0)
dHCPOnly (1)
automatic (2)
*RunIPaddr
710.3.3. 11.5
(*IpParams 5)
Applicable to all products. Read-only: The run-time IP
address. If DHCP is used the Run Time IP Address is the
address given to the unit by the server. Otherwise it is the
manualy configured address.
IP address
*RunSubNetMask
710.3.3. 11.6
(*IpParams 6)
Applicable to all products. Read-only: The run-time Subnet
Mask. If DHCP is used the Run Time Subnet Mask is the
mask given to the unit by the server. Otherwise it is the
manualy configured mask.
IP address
*RunDefaultIPGateway
710.3.3. 11.7
(*IpParams 7)
Applicable to all products. Read-only: The run-time Gateway
IP address. If DHCP is used the Run Time Gateway IP
Address is the address given to the unit by the server.
Otherwise it is the manualy configured address.
IP address
*AccessToDHCP
710.3.3. 11.8
(*IpParams 8)
Applicable to all products. The port to be used for
communicating with a DHCP server. (In GU only the
fromEthernetOnly option is available).
Integer
fromWlanOnly(0)
fromEthernetOnly(1)
fromBoth(2)
MIB Parameter
(Location in Parenthesis)
Description Values/Range
*SysInfo
710.3.3. 13 (brzAccessMib 13)
*UnitHwVersion
710.3.3. 13.1
(*SysInfo 1)
Applicable to all products. Read-only:
Hardware platform version.
DisplayString
(SIZE(0..32))
*VoiceHwVersion
710.3.3. 13.2
(*SysInfo 2)
Applicable only to SU with voice. Read-only:
Voice hardware platform version.
DisplayString
(SIZE(0..32))
*SoftwareVersion
710.3.3. 13.3
(*SysInfo 3)
Applicable to all products. Read-only: Running
software version.
DisplayString
(SIZE(0..32))
*ShadowVersion
710.3.3. 13.4
(*SysInfo 4)
Applicable to all products. Read-only: Shadow
software version.
DisplayString
(SIZE(0..32))
*SupportedMibVersion
710.3.3. 13.5
(*SysInfo 5)
Applicable to all products. Read-only: The
supported private MIB versions.
DisplayString
(SIZE(0..32))
*UnitMacAddress
710.3.3. 13.6
(*SysInfo 6)
Applicable to all products. Read-only, Unit
hardware MAC address.
MAC address