Instruction manual
C-34
BreezeACCESS Version 4.3 System Manual
Manual Revision: 4.0
Unit Control Parameters
MIB Parameter
(Location in Parenthesis)
Description Values/Range
*UnitControl
710.3.3. 10
(brzAccessMib 10)
*ResetUnit
710.3.3. 10.1
(*UnitControl 1)
Applicable to all products. Resets
the unit and applies new parameter
values.
Integer
cancel (0)
resetSystemNow (1)
*SetDefaults
710.3.3. 10.2
(*UnitControl 2)
Applicable to all products. Sets unit
configuration to Defaults values
after the next reset.
completeFactory: All parameters
revert to Factory Defaults values
partialFactory: All parameters revert
to Factory Defaults values, except
the parameters required for
maintaining wireless connectivity.
completeOperator: All parameters
revert to Operator Defaults values
partialOperator: All parameters
revert to Operator Defaults values,
except the parameters required for
maintaining wireless connectivity.
Integer
cancel (0)
completeFactory (1)
partialFactory (2)
completeOperator (1)
partialOperator (2)
*UnitName
710.3.3. 10.3
(*UnitControl 3)
Applicable to all products. The unit
name.
DisplayString (SIZE(32))
A string of up to 32 printable ASCII
characters.
*FlashMemoryControl
710.3.3. 10.4
(*UnitControl 4)
Applicable to all products. Reset
And Boot From Shadow Version:
Activates the backup version.
Use Current Version After Reset :
The currently active version is
activated after reset.
Integer
Cancel (0)
resetAndBootFrom
ShadowVersion (1)
useCurrentVersion
AfterReset (2)
*ConsoleSpeed
710.3.3. 10.5
(*UnitControl 5)
Applicable to all products. The
communication speed of the Monitor
port.
Integer
s9600bps (1)
s19200bps (2)
s38400bps (3)
s57600bps (4)
s115200bps (5)
*MonitorLogoutTimer
710.3.3. 10.6
(*UnitControl 6)
Applicable to all products. Time-out
of management programs (Monitor,
Tel ne t).
Automatic exit if the program is
inactive for the defined time.
Integer
1-999 (minutes)
*UnitPasswords
710.3.3. 10.7
(*UnitControl 7)
*ReadOnlyPassword
710.3.3. 10.7.1
(*UnitPasswords 1)
Applicable to all products. The User
(read only) password.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*InstallerPassword
710.3.3. 10.7.2
(*UnitPasswords 2)
Applicable to all products. The
Installer password.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*AdminPassword
710.3.3. 10.7.3
(*UnitPasswords 3)
Applicable to all products. The
Administrator password. This is also
the SNMP Write Community String.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*EventLog
710.3.3. 10.10
(*UnitControl 10)
Applicable to all products. Event Log
parameters
*EventLogPolicy
710.3.3. 10.10.1
(*EventLog 1)
Applicable to all products.
Determines which events will be
stored in the Event Log. Event from
the configured level and higher are
stored and can be displayed using
the Monitor or by getting a the log
file using TFTP.
Integer
logAll (1)
message (2)
warning (3)
error (4)
fatal (5)
logNone (6)
*NumberOfEventsInLogFile
710.3.3. 10.10.2
(*EventLog 2)
Applicable to all products. Read-
only. The number of events in the
Event Log file.
Integer